Model code decoder

Paste the model code from a pump's nameplate and read what it says: capacity, motor, timer, reservoir and options. It reads the ordering scheme published in each factory manual, for the TZ, HL, GM and ZJ pumps.

TZ type oil lubrication pump

How a TZ code is read

From the ordering guide in the factory manual (PDF). See the TZ Type Oil Lubrication Pump for the specification.

What each position of a TZ model code means
PositionWhat the code says
Discharge capacity
  • 2 110 ml/min at 50 Hz (130 at 60 Hz)
  • 3 220 ml/min at 50 Hz (260 at 60 Hz)
The guide gives no figures for this position. These come from the specification table in the same manual.
Motor poles
  • 2 2-pole motor
Timer module
  • 0 No timer module
  • 1 Built-in microcomputer timer (free setting of action and interval)
  • 3 NK-3 timer with digital display and buttons
The guide's own list says 'without' against both 0 and 1. The manual's model notes say TZ-2211, 2212, 3211 and 3212 carry the built-in microcomputer, so 1 is read as fitted.
Motor supply
  • 1 Single phase 100 V
  • 2 Single phase 220 V
  • 3 Three phase 200 V
  • 4 Three phase 380 V
Reservoir
  • 2 2 L
  • 4 4 L
Pressure switch
  • 10 Switch acts at 10 kgf/cm²
  • 05 Switch acts at 5 kgf/cm²
  • 00 No pressure switch
Pressure take-off
  • X Built-in pressure take-off (for volumetric distributors)
  • T No pressure take-off (for resist-type distributors)
Motor option
  • A Motor option A (the factory guide gives no further detail)
  • No letter: induction motor
Buzzer
  • B With buzzer (TZ-2202 series)
  • No letter: no buzzer
Level switch
  • D Level switch: up is on
  • No letter: level switch: down is on

Worked example from the guide. TZ-2232-410X is read as 2 2 3 2 4 10 X: A TZ pump with a single phase 220 V motor and the NK-3 digital timer, a 4 L reservoir, a pressure switch acting at 10 kgf/cm² and a built-in pressure take-off.

HL type oil lubrication pump

How a HL code is read

From the ordering guide in the factory manual (PDF). See the HL Type Oil Lubrication Pump for the specification.

What each position of a HL model code means
PositionWhat the code says
Discharge capacity
  • 1 0 to 100 cc/min
  • 2 100 to 200 cc/min
  • 3 200 to 300 cc/min
Motor poles
  • 2 2-pole motor
Timer module
  • 0 No timer module
  • 1 Built-in dual-timer module
The guide's own list says 'without' against both 0 and 1. Its worked example, HL-2212-210X, reads 1 as 'with built-in dual-timer module', so 1 is read as fitted.
Motor supply
  • 1 Single phase 100 V
  • 2 Single phase 220 V
Reservoir
  • 2 2 L
  • 4 4 L
Pressure switch
  • 10 Switch acts at 10 kgf/cm²
  • 05 Switch acts at 5 kgf/cm²
  • 00 No pressure switch
Pressure take-off
  • X Built-in pressure take-off
  • T No pressure take-off
Level switch
  • D Level switch: up is on
  • No letter: level switch: down is on

Worked example from the guide. HL-2212-210X is read as 2 2 1 2 2 10 X: An HL pump delivering 100 to 200 cc/min, with a single phase 220 V motor and built-in dual-timer module, a 2 L reservoir, a pressure switch acting at 10 kgf/cm² and a built-in pressure take-off.

GM type grease lubrication pump

How a GM code is read

From the ordering guide in the factory manual (PDF). See the GM Type Grease Lubrication Pump for the specification.

What each position of a GM model code means
PositionWhat the code says
Discharge capacity
  • 2 100 to 200 cc/min
  • 3 200 to 300 cc/min
  • 4 300 to 400 cc/min
Motor poles
  • 2 2-pole motor
Timer module
  • 0 No timer module
  • 1 Built-in dual-timer module
  • 3 NK-3 timer with digital display and buttons (4 L pump only)
Motor supply
  • 1 Single phase 100 V
  • 2 Single phase 220 V
  • 3 Three phase 200 V
  • 4 Three phase 380 V
Reservoir
  • 2 2 L
  • 4 4 L
Pressure switch
  • 30 Switch acts at 30 kgf/cm²
  • 00 No pressure switch
Pressure take-off
  • X Built-in pressure take-off (for use with a dosing distributor)
  • T No pressure take-off (for use with a resist-type distributor)
Level sensor
  • S With capacitance-type level sensor
  • No letter: no level sensor

Worked example from the guide. GM-3204-230X is read as 3 2 0 4 2 30 X: A GM grease pump delivering 200 to 300 cc/min, with no timer module and a three phase 380 V motor, a 2 L reservoir, a pressure switch acting at 30 kgf/cm² and a built-in pressure take-off.

ZJ type high-pressure grease pump

How a ZJ code is read

From the ordering guide in the factory manual (PDF). See the ZJ Type High Pressure Grease Pump for the specification.

What each position of a ZJ model code means
PositionWhat the code says
Discharge capacity
  • 3 2 to 3 mL/min (single pumping unit)
  • 6 4 to 6 mL/min (double pumping unit)
Motor
  • 5 DC 12 V
  • 6 DC 24 V
Controller
  • 0 No controller
  • 1 Time-programming controller
  • 2 Time-travel controller
Reservoir
  • 2 2 L (1.9 kg)
  • 3 2.5 L
  • 4 4 L (4 kg)
  • 8 8 L (8 kg)
Chassis
  • P High-strength plastic chassis
  • No letter: aluminium alloy chassis
Level switch
  • S With level switch
  • No letter: no level switch
Output
  • V Adjustable output
  • No letter: fixed output stroke

Worked example from the guide. ZJ3612S is read as 3 6 1 2 S: A ZJ grease pump delivering 2 to 3 mL/min from a single pumping unit, with a DC 24 V motor, a time-programming controller, a 2 L reservoir, an aluminium alloy chassis, a level switch and a fixed output stroke.

What this does not cover

When a code will not decode

Everything above comes from the ordering guide in each factory manual, and only from there. The India range also includes variants those guides do not list: the TZ pump, for instance, is supplied here for 24 V DC, 110 V AC and 415 V three-phase, none of which has a code in the guide. A code outside the scheme is shown as such rather than guessed at.

The 34, 35 and RH-3 distributors give their outlet capacities digit by digit in a code of variable length, and the guides for the other pumps either publish no scheme or one we have not encoded yet. For any of those, or a code that stops decoding partway, send us the nameplate.

Code not on this page?

Send us the nameplate, or a photograph of it, with the machine it came off. We will read it and come back with the replacement.

Send us the nameplate

We reply by email, usually within a working day.

Send us the nameplate